GPR3000 Power Reference
Unit:
The circuitry is housed
within a 2U 19 inch rack unit having visual indications
on the front panel for the internal circuitry and clean
contact alarms via a 25 pin D type connector on the
rear.
Internal circuitry
monitors the following status for each circuit:
Block up converter current. If
the Block Upconverter looses lock with the 10MHZ crystal
it will Mute its output. If this happens the current
drawn from the GPR3000 will reduce from approximately
1.2A to 300mA and generate a ‘BUC’ alarm within the
unit.
The crystals within the unit also
provide alarms when the oven temperature is not within
specification (this will happen for a while after switch
on) and if the RF power on the 10MHz signal is low.
The Power supplies within the unit
are also monitored and in the event of a failure will
produce a visual and clean contact alarm.
Visual Indications: LED
on front panel
|
(if
fitted) |
BUC 1 |
BUC 2 |
Oven 1 |
Oven 2 |
10 MHz Ref RF
1 |
10 MHz Ref RF
2 |
PSU 1 |
PSU
2 |
|

|
The 10MHZ crystal frequency has
electrical and mechanical adjustment. In the event of
the crystal aging it may be necessary to adjust the
oscillator frequency. A potentiometer mounted on the
rear panel of the unit will electrically adjust the
frequency of oscillation, however the accuracy of the
crystal will be as good or better than the measurement
equipment and it is therefore recommended to monitor
the ku band signals when adjusting the potentiometer.
When delivered the adjustment is
set to its central position, it is not expected that
physical adjustment will be needed but in this eventuality,
access can be obtained to the crystal body by removing
the top cover of the unit.
It is recommended that the transmit
frequency is checked and adjusted every 6 months. In
the event that, because of the nature of the service,
it is not possible to measure the transmit frequency
Eutelsat and Intelsat
will help in ensuring that the transmit frequency is
correct by monitoring the signals on the satellite and
advising whether adjustment is necessary. Call the CSC
in Eutelsat on +33 1 45570666 for support.
 TPR3000
Alarm Connections
Pin number |
Condition |
Alarm |
|
1 |
N/C |
|
|
2 |
N/O |
PSU 1 |
|
3 |
Com |
|
|
4 |
N/C |
|
|
5 |
N/O |
PSU 2 |
|
6 |
Com |
|
|
7 |
N/C |
|
|
8 |
N/O |
BUC 1 |
|
9 |
Com |
|
|
10 |
Com |
|
|
11 |
N/O |
BUC 2 |
(if fitted) |
12 |
N/C |
|
|
13 |
N/C |
|
|
14 |
N/O |
Xtal
RF Power 1 |
|
15 |
Com |
|
|
16 |
N/C |
|
|
17 |
N/O |
Xtal
Oven Temp 1 |
|
18 |
Com |
|
|
19 |
N/C |
|
|
20 |
N/O |
Xtal RF Power
2 |
(if fitted) |
21 |
Com |
|
|
22 |
N/C |
|
|
23 |
N/O |
Xtal
Oven Temp 2 |
(if fitted) |
24 |
Com |
|
|
25 |
N/Used |
|
|
Specification:
Physical: Size:
19 inch rack unit, 2U, 350mm deep. Weight:
2.5 Kg. Power: Mains:
220-240V AC Consumption:
25W (typical)
Indications:
Front panel:
Status LEDs. Contacts:
Form C contacts for alarm conditions.
Reference
(10MHz): Frequency stability /day:
1 x 10-9 Phase Noise:
dBc/Hz Offset 10Hz.
-120
100Hz.
-130
1kHz.
-150
10kHz.
-155
100kHz.
-155 10MHz Power
+3 to +7dBm
L
Band: Frequency
950 -1450MHz Through Loss
3-5dB.
DC
supply power: +24 V @ 2A (BUC supply)
Connections:
Mains:
IEC. L band i/p 1 & 2:
N type ‘F’ L band o/p 1 & 2:
N type ‘F’ Alarms:
25W D.
|